Power and charging
Ingenico Link/2500: turn on, turn off, restart and charge
How to turn the Ingenico Link/2500 on and off, restart it, and charge its battery over USB-C, with Ingenico's checks when it will not power on.
- Applies to
- Ingenico Link/2500, Link/2500 LE, Link/2500i LE
- Last reviewed
- Oct 27, 2026 by Abdul Rashid
Exact messages this covers
Alert Irruption!
Check first
- Is it a standard Link/2500, or a Slim or Integration version?
- Does the screen respond to key presses?
- Does the battery symbol flash or move when the power supply is connected?
To turn off an Ingenico Link/2500, press the minus key (right of 0) and the yellow key together for one second. To turn it on or restart it, press the green key. If it is frozen, switch it off with that combination and press green to start it again.
The Link/2500 also shuts off by itself when its battery is empty. A restart is not a factory reset; never attempt a factory reset on an injected terminal, because it wipes the encryption keys.
Before you start
- On a new terminal, charge the battery for 4 hours before first use, as Ingenico advises.
- Use only the power supply that came with the terminal.
- Battery: Li-ion 1200 mAh on the standard version (600 mAh on Slim and Integration versions); 80% charge in about 1 hour, full in about 1.5 hours on the supplied 1 A supply.
Steps
- If a sale is on screen and the keys respond, press the red key to cancel it. Expected: the terminal returns to idle.
- Press the minus key (bottom row, right of 0) and the yellow key together for one second. Expected: the screen goes off and the terminal shuts down.
- Press the green key. Expected: the terminal starts and loads its payment application.
- Connect the supplied power supply to the USB-C port on the right side and plug it into the wall. Expected: the battery symbol flashes or moves (charging).
If that did not work
Ingenico's checks when the Link/2500 does not turn on: confirm the battery is connected and not fully discharged, and connect the power supply. A fully discharged battery can take a long time to recover, so leave it on charge. Charge away from heat sources, ideally at 15 to 25 °C. If "Alert Irruption!" appears, stop and contact support. Otherwise contact Allstar support with the model, serial number, payment application, processor and the exact message on screen.
Sources
- Link/2500 LE - Link/2500i LE User Guide (900055504 R11 000 01/0224)
- Link 2500 / Link 2500 I User Guide (900036315 R11 000 05/1022)
- Ingenico resources: Link/2500 LE series
Stop and contact support if
- The screen repeatedly flashes "Alert Irruption!": tampering detected. Stop, do not restart it repeatedly, and contact support.
- It does not power on after charging: contact support.
- It freezes after every restart: contact support. Do not attempt a factory reset; on an injected terminal it wipes the encryption keys and the terminal must be re-injected.
Contact Allstar support with the model, serial number, payment application, processor and the exact message on screen.
Notes
- The off-key is shown as an icon in Ingenico's guide; rendered at high resolution it is the key marked with a minus sign, to the right of 0 on the Link/2500 LE keypad. On other Ingenico models the same combination uses the dot key.
- Bluetooth pairing is not covered: no Ingenico document read gives pairing steps (pairing is done from the payment application). See the gap log.
- Ingenico's "Link/2500 - How to turn on/off" resource page (published 10 Apr 2023) carries a video only; its content could not be read and is not cited.
- The charging port is USB-C on the Link/2500 LE guide and also on the 2022 Link/2500 guide; older Link/2500 units in the field may differ. VERIFY-BY checking stocked units.
Sources
- Link/2500 LE - Link/2500i LE User Guide, 2.3 Keyboard, 3.1 Switching off the terminal, 4.5 Battery, 11 Troubleshooting · 900055504 R11 000 01/0224 · 2024-02-01 · read 2026-10-26 · manufacturer documentation
- Link 2500 / Link 2500 I User Guide, 3.1 Switching off the terminal · 900036315 R11 000 05/1022 · 2022-10-01 · read 2026-10-26 · manufacturer documentation
- Ingenico resources: Link/2500 LE series · 2022-11-15 · read 2026-10-26 · manufacturer documentation
Was this guide helpful?
Thanks. The team reviews this feedback.